Aleta.hr
Main Product Image

2CDS384001R0488 | S304P-Z20

Code: 1997482

ManufacturerABB
Catalog number2CDS384001R0488
EAN code4016779135535

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles4
Rated voltage415V
Number of poles (total)4
Built-in depth69mm
Rated current20A
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeOther
Rated impulse withstand voltage Uimp6kV
Release characteristicZ
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Frequency50 - 60Hz
Power loss10W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Current limiting class-
Additional equipment possibleYes
Over voltage category4
Pollution degree3
Degree of protection (IP)IP20
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Ambient temperature during operating-40 - 70°C
Width in number of modular spacings4.0
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0488 | S304P-Z20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

4

Rated voltage

415V

Number of poles (total)

4

Built-in depth

69mm

Rated current

20A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Rated impulse withstand voltage Uimp

6kV

Release characteristic

Z

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Power loss

10W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Current limiting class

-

Additional equipment possible

Over voltage category

4

Pollution degree

3

Degree of protection (IP)

IP20

Flush-mounted installation

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 70°C

Width in number of modular spacings

4.0

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.