Aleta.hr
Main Product Image

2CDS384001R0505 | S304P-B50

Code: 1997485

ManufacturerABB
Catalog number2CDS384001R0505
EAN code4016779076074

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles4
Rated insulation voltage Ui500V
Release characteristicB
Rated current50A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated voltage415V
Built-in depth69mm
Number of poles (total)4
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Frequency50 - 60Hz
Current limiting class-
Power loss14.8W
Flush-mounted installationNo
Pollution degree3
Additional equipment possibleYes
Over voltage category4
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings4.0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0505 | S304P-B50

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

4

Rated insulation voltage Ui

500V

Release characteristic

B

Rated current

50A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated voltage

415V

Built-in depth

69mm

Number of poles (total)

4

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Frequency

50 .. 60Hz

Current limiting class

-

Power loss

14.8W

Flush-mounted installation

Pollution degree

3

Additional equipment possible

Over voltage category

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

4.0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.