Aleta.hr
Main Product Image

2CDS384001R0518 | S304P-Z25

Code: 1997487

ManufacturerABB
Catalog number2CDS384001R0518
EAN code4016779076050

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicZ
Rated insulation voltage Ui500V
Number of protected poles4
Built-in depth69mm
Rated voltage415V
Rated current25A
Rated impulse withstand voltage Uimp6kV
Number of poles (total)4
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Power loss13.2W
Frequency50 - 60Hz
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Width in number of modular spacings4.0
Additional equipment possibleYes
Pollution degree3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
Over voltage category4
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0518 | S304P-Z25

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Rated insulation voltage Ui

500V

Number of protected poles

4

Built-in depth

69mm

Rated voltage

415V

Rated current

25A

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

4

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

13.2W

Frequency

50 .. 60Hz

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Width in number of modular spacings

4.0

Additional equipment possible

Pollution degree

3

Flush-mounted installation

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Over voltage category

4

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.