Technical specifications

Release characteristicK
Built-in depth69mm
Number of poles (total)4
Rated voltage415V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Rated current32A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V20kA
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Frequency50 - 60Hz
Voltage typeOther
Power loss11.6W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Current limiting class-
Width in number of modular spacings4.0
Flush-mounted installationNo
Additional equipment possibleYes
Over voltage category4
Ambient temperature during operating-40 - 70°C
Pollution degree3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0537 | S304P-K32

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Built-in depth

69mm

Number of poles (total)

4

Rated voltage

415V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated current

32A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Voltage type

Other

Power loss

11.6W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Current limiting class

-

Width in number of modular spacings

4.0

Flush-mounted installation

Additional equipment possible

Over voltage category

4

Ambient temperature during operating

-40 .. 70°C

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof