Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current32A
Over voltage category4
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Rated voltage415V
Release characteristicZ
Built-in depth69mm
Pollution degree3
Current limiting class-
Voltage typeOther
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Number of protected poles4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V20kA
Degree of protection (IP)IP20
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Ambient temperature during operating-40 - 70°C
Power loss12.4W
Width in number of modular spacings4.0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0538 | S304P-Z32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

32A

Over voltage category

4

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Rated voltage

415V

Release characteristic

Z

Built-in depth

69mm

Pollution degree

3

Current limiting class

-

Voltage type

Other

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Number of protected poles

4

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA

Degree of protection (IP)

IP20

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Ambient temperature during operating

-40 .. 70°C

Power loss

12.4W

Width in number of modular spacings

4.0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.