Aleta.hr
Main Product Image

2CDS384001R0558 | S304P-Z40

Code: 1997491

ManufacturerABB
Catalog number2CDS384001R0558
EAN code4016779076012

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage415V
Rated current40A
Number of protected poles4
Release characteristicZ
Number of poles (total)4
Built-in depth69mm
Rated impulse withstand voltage Uimp6kV
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V20kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss19.6W
Voltage typeOther
Rated insulation voltage Ui500V
Additional equipment possibleYes
Width in number of modular spacings4.0
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Over voltage category4
Connectable conductor cross section multi-wired0.75 - 25mm²
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
Explosion-proofNo
Ambient temperature during operating-40 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0558 | S304P-Z40

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Rated current

40A

Number of protected poles

4

Release characteristic

Z

Number of poles (total)

4

Built-in depth

69mm

Rated impulse withstand voltage Uimp

6kV

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

19.6W

Voltage type

Other

Rated insulation voltage Ui

500V

Additional equipment possible

Width in number of modular spacings

4.0

Concurrently switching neutral conductor

Flush-mounted installation

Over voltage category

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Explosion-proof

Ambient temperature during operating

-40 .. 70°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.