  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Built-in depth69mm
Rated voltage415V
Power loss20.8W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated insulation voltage Ui500V
Rated current50A
Release characteristicZ
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Voltage typeOther
Current limiting class-
Additional equipment possibleYes
Over voltage category4
Pollution degree3
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Width in number of modular spacings4.0
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0578 | S304P-Z50

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Built-in depth

69mm

Rated voltage

415V

Power loss

20.8W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated insulation voltage Ui

500V

Rated current

50A

Release characteristic

Z

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Current limiting class

-

Additional equipment possible

Over voltage category

4

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Flush-mounted installation

Width in number of modular spacings

4.0

Explosion-proof