Aleta.hr
Main Product Image

2CDS384001R0607 | S304P-K63

Code: 1997494

ManufacturerABB
Catalog number2CDS384001R0607
EAN code4016779075985

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Built-in depth69mm
Number of poles (total)4
Rated current63A
Rated impulse withstand voltage Uimp6kV
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V63kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated insulation voltage Ui500V
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Frequency50 - 60Hz
Current limiting class-
Rated voltage415V
Power loss24W
Pollution degree3
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Additional equipment possibleYes
Over voltage category4
Width in number of modular spacings4.0
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0607 | S304P-K63

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Built-in depth

69mm

Number of poles (total)

4

Rated current

63A

Rated impulse withstand voltage Uimp

6kV

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

63kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated insulation voltage Ui

500V

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Current limiting class

-

Rated voltage

415V

Power loss

24W

Pollution degree

3

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible

Over voltage category

4

Width in number of modular spacings

4.0

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Flush-mounted installation

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.