  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Number of conductors (without earthing)-
Lightning impulse current (10/350 µs)35kA
With remote signalling contactNo
Max. continuous voltage AC440V
ExhaustingNo
Max. continuous voltage DC-V
System configuration TNYes
Integrated backup fuseNo
Suitable for outdoor useNo
Voltage protection level (DC+ - DC-)-kV
Nominal voltage DC-V
Nominal voltage AC400V
Voltage protection level N-PE-kV
Max. conductor cross section flexible (fine-strand)-mm²
System configuration ITNo
Specific energy (W/R)-kJ/Ohm
Degree of protection (IP)IP20
Voltage protection level (DC+/DC- - PE)-kV
Voltage protection level L-N-kV
Max. conductor cross section solid (solid, stranded)-mm²
Signalling at the deviceOptic
Voltage protection level2.5kV
Category type 1Yes
System configuration DCNo
Nominal discharge surge current (8/20)35kA
System configuration TN-SNo
System configuration TN-CYes
Follow current extinguishing capability50kA
System configuration otherNo
System configuration TTNo
System configuration TN-C-SNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5096974 | MCF 35-1+FS-440

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Lightning current arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

Number of conductors (without earthing)

-

Lightning impulse current (10/350 µs)

35kA

With remote signalling contact

Max. continuous voltage AC

440V

Exhausting

Max. continuous voltage DC

-V

System configuration TN

Integrated backup fuse

Suitable for outdoor use

Voltage protection level (DC+ - DC-)

-kV

Nominal voltage DC

-V

Nominal voltage AC

400V

Voltage protection level N-PE

-kV

Max. conductor cross section flexible (fine-strand)

-mm²

System configuration IT

Specific energy (W/R)

-kJ/Ohm

Degree of protection (IP)

IP20

Voltage protection level (DC+/DC- - PE)

-kV

Voltage protection level L-N

-kV

Max. conductor cross section solid (solid, stranded)

-mm²

Signalling at the device

Optic

Voltage protection level

2.5kV

Category type 1

System configuration DC

Nominal discharge surge current (8/20)

35kA

System configuration TN-S

System configuration TN-C

Follow current extinguishing capability

50kA

System configuration other

System configuration TT

System configuration TN-C-S

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.