Technical specifications

Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Built-in depth82.5mm
Rated current13A
Number of protected poles1
Number of poles (total)1
Rated voltage-V
Rated insulation voltage Ui1000V
Release characteristicK
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Power loss2W
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Pollution degree2
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Width in number of modular spacings1.5
Over voltage category3
Flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019008R0001 | S801HV-K13

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Built-in depth

82.5mm

Rated current

13A

Number of protected poles

1

Number of poles (total)

1

Rated voltage

-V

Rated insulation voltage Ui

1000V

Release characteristic

K

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Power loss

2W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Pollution degree

2

Additional equipment possible

Concurrently switching neutral conductor

Width in number of modular spacings

1.5

Over voltage category

3

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.