Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage-V
Rated insulation voltage Ui1000V
Rated current100A
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Built-in depth82.5mm
Number of poles (total)1
Number of protected poles1
Release characteristicK
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Voltage typeOther
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss8W
Current limiting class3
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Over voltage category3
Width in number of modular spacings1.5
Pollution degree2
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 70mm²
Explosion-proofNo
Connectable conductor cross section multi-wired0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019017R0001 | S801HV-K100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

-V

Rated insulation voltage Ui

1000V

Rated current

100A

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Built-in depth

82.5mm

Number of poles (total)

1

Number of protected poles

1

Release characteristic

K

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Voltage type

Other

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

8W

Current limiting class

3

Concurrently switching neutral conductor

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Over voltage category

3

Width in number of modular spacings

1.5

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.