Voltage typeOther
Release characteristicK
Number of protected poles1
Rated voltage-V
Built-in depth82.5mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Rated current125A
Rated insulation voltage Ui1000V
Power loss9.4W
Current limiting class3
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Over voltage category3
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Pollution degree2
Additional equipment possibleYes
Width in number of modular spacings1.5
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Connectable conductor cross section solid-core0 - 70mm²
Connectable conductor cross section multi-wired0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019018R0001 | S801HV-K125

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Release characteristic

K

Number of protected poles

1

Rated voltage

-V

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Rated current

125A

Rated insulation voltage Ui

1000V

Power loss

9.4W

Current limiting class

3

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Over voltage category

3

Concurrently switching neutral conductor

Flush-mounted installation

Pollution degree

2

Additional equipment possible

Width in number of modular spacings

1.5

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²

Connectable conductor cross section multi-wired

0 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.