Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Release characteristicK
Rated current8A
Rated voltage-V
Number of protected poles2
Rated insulation voltage Ui1000V
Voltage typeOther
Rated impulse withstand voltage Uimp8kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss3.4W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Over voltage category3
Flush-mounted installationNo
Pollution degree2
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Connectable conductor cross section multi-wired0 - 50mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019020R0001 | S802HV-K8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

K

Rated current

8A

Rated voltage

-V

Number of protected poles

2

Rated insulation voltage Ui

1000V

Voltage type

Other

Rated impulse withstand voltage Uimp

8kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

3.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Over voltage category

3

Flush-mounted installation

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

0 .. 50mm²

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.