Aleta.hr
Main Product Image

2CCF019022R0001 | S802HV-K13

Code: 1998975

ManufacturerRAZNO
Catalog number2CCF019022R0001
Type
EAN code7612271436704

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Built-in depth

82.5mm

Release characteristic

K

Number of protected poles

2

Rated current

13A

Rated voltage

-V

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

1000V

Power loss

4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 - 60Hz

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Over voltage category

3

Concurrently switching neutral conductor

No

Flush-mounted installation

No

Ambient temperature during operating

-25 - 60°C

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Pollution degree

2

Connectable conductor cross section solid-core

0 - 70mm²

Explosion-proof

No

Connectable conductor cross section multi-wired

0 - 50mm²

Additional equipment possible

Yes


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCF019022R0001 | S802HV-K13

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Built-in depth

82.5mm

Release characteristic

K

Number of protected poles

2

Rated current

13A

Rated voltage

-V

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

1000V

Power loss

4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Over voltage category

3

Concurrently switching neutral conductor

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Pollution degree

2

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

Additional equipment possible

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.