Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Release characteristicK
Rated insulation voltage Ui1000V
Voltage typeOther
Rated voltage-V
Frequency50 - 60Hz
Rated current63A
Over voltage category3
Explosion-proofNo
Pollution degree2
Number of protected poles2
Power loss12.8W
Degree of protection (IP)IP20
Current limiting class3
Width in number of modular spacings3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 50mm²
Number of poles (total)2
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Connectable conductor cross section solid-core0 - 70mm²
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019029R0001 | S802HV-K63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

K

Rated insulation voltage Ui

1000V

Voltage type

Other

Rated voltage

-V

Frequency

50 .. 60Hz

Rated current

63A

Over voltage category

3

Explosion-proof

Pollution degree

2

Number of protected poles

2

Power loss

12.8W

Degree of protection (IP)

IP20

Current limiting class

3

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 50mm²

Number of poles (total)

2

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Connectable conductor cross section solid-core

0 .. 70mm²

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.