Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles3
Built-in depth82.5mm
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Voltage typeOther
Release characteristicK
Rated voltage-V
Rated current125A
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui1000V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Frequency50 - 60Hz
Current limiting class3
Power loss28.2W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Over voltage category3
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
Pollution degree2
Width in number of modular spacings4.5
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019046R0001 | S803HV-K125

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

3

Built-in depth

82.5mm

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Release characteristic

K

Rated voltage

-V

Rated current

125A

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

1000V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

50 .. 60Hz

Current limiting class

3

Power loss

28.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²

Pollution degree

2

Width in number of modular spacings

4.5

Additional equipment possible

Concurrently switching neutral conductor

Explosion-proof