Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current10A
Built-in depth82.5mm
Rated voltage-V
Voltage typeOther
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section solid-core0 - 50mm²
Power loss0.81W
Rated insulation voltage Ui690V
Pollution degree2
Number of protected poles3
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Over voltage category3
Current limiting class3
Number of poles (total)3
Ambient temperature during operating-25 - 60°C
Release characteristicKM
Width in number of modular spacings4.5
Flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019559R0001 | S803S-KM10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

10A

Built-in depth

82.5mm

Rated voltage

-V

Voltage type

Other

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section solid-core

0 .. 50mm²

Power loss

0.81W

Rated insulation voltage Ui

690V

Pollution degree

2

Number of protected poles

3

Concurrently switching neutral conductor

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Over voltage category

3

Current limiting class

3

Number of poles (total)

3

Ambient temperature during operating

-25 .. 60°C

Release characteristic

KM

Width in number of modular spacings

4.5

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.