  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated current1.6A
Number of protected poles1
Power loss2.9W
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Frequency50 - 60Hz
Rated voltage230V
Rated impulse withstand voltage Uimp8kV
Release characteristicB
Rated insulation voltage Ui690V
Built-in depth82.5mm
Over voltage category4
Flush-mounted installationYes
Additional equipment possibleYes
Pollution degree3
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0 - 50mm²
Width in number of modular spacings1.5
Degree of protection (IP)IP20
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019843R0001 | S801S-B1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated current

1.6A

Number of protected poles

1

Power loss

2.9W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Frequency

50 .. 60Hz

Rated voltage

230V

Rated impulse withstand voltage Uimp

8kV

Release characteristic

B

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Over voltage category

4

Flush-mounted installation

Additional equipment possible

Pollution degree

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 50mm²

Width in number of modular spacings

1.5

Degree of protection (IP)

IP20

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.