Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Additional equipment possibleYes
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Number of protected poles1
Pollution degree3
Rated voltage230V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired0 - 50mm²
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Built-in depth82.5mm
Connectable conductor cross section solid-core0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Frequency50 - 60Hz
Current limiting class3
Flush-mounted installationYes
Power loss1.6W
Rated insulation voltage Ui690V
Width in number of modular spacings1.5
Degree of protection (IP)IP20
Over voltage category4
Rated impulse withstand voltage Uimp8kV
Rated current1A
Release characteristicC
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019850R0001 | S801S-C1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Additional equipment possible

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of protected poles

1

Pollution degree

3

Rated voltage

230V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Built-in depth

82.5mm

Connectable conductor cross section solid-core

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Power loss

1.6W

Rated insulation voltage Ui

690V

Width in number of modular spacings

1.5

Degree of protection (IP)

IP20

Over voltage category

4

Rated impulse withstand voltage Uimp

8kV

Rated current

1A

Release characteristic

C

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.