Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree3
Rated voltage230V
Current limiting class3
Rated current1.6A
Over voltage category4
Rated insulation voltage Ui690V
Release characteristicC
Degree of protection (IP)IP20
Number of protected poles1
Frequency50 - 60Hz
Width in number of modular spacings1.5
Voltage typeOther
Power loss2.9W
Built-in depth82.5mm
Explosion-proofNo
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0 - 50mm²
Rated impulse withstand voltage Uimp8kV
Flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Connectable conductor cross section solid-core0 - 70mm²
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of poles (total)1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019851R0001 | S801S-C1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

3

Rated voltage

230V

Current limiting class

3

Rated current

1.6A

Over voltage category

4

Rated insulation voltage Ui

690V

Release characteristic

C

Degree of protection (IP)

IP20

Number of protected poles

1

Frequency

50 .. 60Hz

Width in number of modular spacings

1.5

Voltage type

Other

Power loss

2.9W

Built-in depth

82.5mm

Explosion-proof

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated impulse withstand voltage Uimp

8kV

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of poles (total)

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.