  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Release characteristicC
Rated voltage230V
Current limiting class3
Rated insulation voltage Ui690V
Built-in depth82.5mm
Voltage typeOther
Rated current2A
Width in number of modular spacings1.5
Pollution degree3
Connectable conductor cross section solid-core0 - 70mm²
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Over voltage category4
Concurrently switching neutral conductorYes
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Flush-mounted installationYes
Explosion-proofNo
Number of protected poles1
Rated impulse withstand voltage Uimp8kV
Power loss2.2W
Connectable conductor cross section multi-wired0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019852R0001 | S801S-C2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Release characteristic

C

Rated voltage

230V

Current limiting class

3

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Voltage type

Other

Rated current

2A

Width in number of modular spacings

1.5

Pollution degree

3

Connectable conductor cross section solid-core

0 .. 70mm²

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Over voltage category

4

Concurrently switching neutral conductor

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Flush-mounted installation

Explosion-proof

Number of protected poles

1

Rated impulse withstand voltage Uimp

8kV

Power loss

2.2W

Connectable conductor cross section multi-wired

0 .. 50mm²