2CCF019852R0001 | S801S-C2

Code: 1999013

ManufacturerABB
Catalog number2CCF019852R0001
EAN code7612271499181

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Release characteristicC
Number of poles (total)1
Number of protected poles1
Rated current2A
Rated voltage230V
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Power loss2.2W
Frequency50 - 60Hz
Current limiting class3
Flush-mounted installationYes
Concurrently switching neutral conductorYes
Over voltage category4
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings1.5
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019852R0001 | S801S-C2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

C

Number of poles (total)

1

Number of protected poles

1

Rated current

2A

Rated voltage

230V

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Power loss

2.2W

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

4

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

1.5

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof