Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Explosion-proofNo
Degree of protection (IP)IP20
Over voltage category4
Pollution degree3
Rated voltage230V
Rated insulation voltage Ui690V
Rated current3A
Current limiting class3
Built-in depth82.5mm
Power loss2.4W
Width in number of modular spacings1.5
Frequency50 - 60Hz
Voltage typeOther
Release characteristicC
Concurrently switching neutral conductorYes
Number of protected poles1
Additional equipment possibleYes
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section solid-core0 - 70mm²
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Ambient temperature during operating-25 - 60°C
Number of poles (total)1
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019854R0001 | S801S-C3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Explosion-proof

Degree of protection (IP)

IP20

Over voltage category

4

Pollution degree

3

Rated voltage

230V

Rated insulation voltage Ui

690V

Rated current

3A

Current limiting class

3

Built-in depth

82.5mm

Power loss

2.4W

Width in number of modular spacings

1.5

Frequency

50 .. 60Hz

Voltage type

Other

Release characteristic

C

Concurrently switching neutral conductor

Number of protected poles

1

Additional equipment possible

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section solid-core

0 .. 70mm²

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

1

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.