Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth82.5mm
Rated current5A
Rated voltage230V
Explosion-proofNo
Frequency50 - 60Hz
Width in number of modular spacings1.5
Pollution degree3
Release characteristicD
Current limiting class3
Over voltage category4
Rated insulation voltage Ui690V
Power loss1.5W
Degree of protection (IP)IP20
Number of protected poles1
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section solid-core0 - 70mm²
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Ambient temperature during operating-25 - 60°C
Flush-mounted installationYes
Number of poles (total)1
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Concurrently switching neutral conductorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019864R0001 | S801S-D5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

82.5mm

Rated current

5A

Rated voltage

230V

Explosion-proof

Frequency

50 .. 60Hz

Width in number of modular spacings

1.5

Pollution degree

3

Release characteristic

D

Current limiting class

3

Over voltage category

4

Rated insulation voltage Ui

690V

Power loss

1.5W

Degree of protection (IP)

IP20

Number of protected poles

1

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section solid-core

0 .. 70mm²

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Number of poles (total)

1

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.