Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth82.5mm
Rated current1.6A
Frequency50 - 60Hz
Release characteristicC
Degree of protection (IP)IP20
Explosion-proofNo
Rated voltage400V
Power loss5.8W
Width in number of modular spacings3
Current limiting class3
Pollution degree3
Rated insulation voltage Ui690V
Over voltage category4
Number of protected poles2
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section solid-core0 - 70mm²
Flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Number of poles (total)2
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019875R0001 | S802S-C1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

82.5mm

Rated current

1.6A

Frequency

50 .. 60Hz

Release characteristic

C

Degree of protection (IP)

IP20

Explosion-proof

Rated voltage

400V

Power loss

5.8W

Width in number of modular spacings

3

Current limiting class

3

Pollution degree

3

Rated insulation voltage Ui

690V

Over voltage category

4

Number of protected poles

2

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section solid-core

0 .. 70mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Number of poles (total)

2

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA