Technical specifications

Built-in depth82.5mm
Rated voltage400V
Current limiting class3
Release characteristicC
Number of protected poles2
Power loss4.8W
Number of poles (total)2
Rated current3A
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp8kV
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Over voltage category4
Width in number of modular spacings3
Concurrently switching neutral conductorYes
Pollution degree3
Flush-mounted installationYes
Degree of protection (IP)IP20
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Connectable conductor cross section solid-core0 - 70mm²
Connectable conductor cross section multi-wired0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019878R0001 | S802S-C3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated voltage

400V

Current limiting class

3

Release characteristic

C

Number of protected poles

2

Power loss

4.8W

Number of poles (total)

2

Rated current

3A

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Over voltage category

4

Width in number of modular spacings

3

Concurrently switching neutral conductor

Pollution degree

3

Flush-mounted installation

Degree of protection (IP)

IP20

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²

Connectable conductor cross section multi-wired

0 .. 50mm²