Technical specifications

Voltage typeOther
Release characteristicD
Number of poles (total)2
Flush-mounted installationYes
Explosion-proofNo
Frequency50 - 60Hz
Built-in depth82.5mm
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section multi-wired0 - 50mm²
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Width in number of modular spacings3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui690V
Power loss4W
Over voltage category4
Ambient temperature during operating-25 - 60°C
Current limiting class3
Number of protected poles2
Pollution degree3
Rated current0.5A
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Connectable conductor cross section solid-core0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019881R0001 | S802S-D0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Release characteristic

D

Number of poles (total)

2

Flush-mounted installation

Explosion-proof

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 50mm²

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

690V

Power loss

4W

Over voltage category

4

Ambient temperature during operating

-25 .. 60°C

Current limiting class

3

Number of protected poles

2

Pollution degree

3

Rated current

0.5A

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Connectable conductor cross section solid-core

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated impulse withstand voltage Uimp

8kV