Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Power loss4.4W
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Built-in depth82.5mm
Release characteristicD
Number of protected poles2
Number of poles (total)2
Rated current2A
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Frequency50 - 60Hz
Rated voltage400V
Concurrently switching neutral conductorYes
Flush-mounted installationYes
Additional equipment possibleYes
Width in number of modular spacings3
Over voltage category4
Connectable conductor cross section solid-core0 - 70mm²
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Connectable conductor cross section multi-wired0 - 50mm²
Degree of protection (IP)IP20
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019884R0001 | S802S-D2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Power loss

4.4W

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Built-in depth

82.5mm

Release characteristic

D

Number of protected poles

2

Number of poles (total)

2

Rated current

2A

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 .. 60Hz

Rated voltage

400V

Concurrently switching neutral conductor

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

3

Over voltage category

4

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

Degree of protection (IP)

IP20

Pollution degree

3