Aleta.hr
Main Product Image

2CCF019884R0001 | S802S-D2

Code: 1999040

ManufacturerRAZNO
Catalog number2CCF019884R0001
Type
EAN code7612271499501

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Power loss

4.4W

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Built-in depth

82.5mm

Release characteristic

D

Number of protected poles

2

Number of poles (total)

2

Rated current

2A

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 - 60Hz

Rated voltage

400V

Concurrently switching neutral conductor

Yes

Flush-mounted installation

Yes

Additional equipment possible

Yes

Width in number of modular spacings

3

Over voltage category

4

Connectable conductor cross section solid-core

0 - 70mm²

Ambient temperature during operating

-25 - 60°C

Explosion-proof

No

Connectable conductor cross section multi-wired

0 - 50mm²

Degree of protection (IP)

IP20

Pollution degree

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCF019884R0001 | S802S-D2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Power loss

4.4W

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Built-in depth

82.5mm

Release characteristic

D

Number of protected poles

2

Number of poles (total)

2

Rated current

2A

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 .. 60Hz

Rated voltage

400V

Concurrently switching neutral conductor

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

3

Over voltage category

4

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

Degree of protection (IP)

IP20

Pollution degree

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.