Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui690V
Release characteristicB
Rated current0.5A
Number of protected poles3
Number of poles (total)3
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss6W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Built-in depth82.5mm
Concurrently switching neutral conductorYes
Pollution degree3
Flush-mounted installationYes
Connectable conductor cross section multi-wired0 - 50mm²
Explosion-proofNo
Connectable conductor cross section solid-core0 - 70mm²
Width in number of modular spacings4.5
Degree of protection (IP)IP20
Over voltage category4
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019889R0001 | S803S-B0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

690V

Release characteristic

B

Rated current

0.5A

Number of protected poles

3

Number of poles (total)

3

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

6W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Built-in depth

82.5mm

Concurrently switching neutral conductor

Pollution degree

3

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 50mm²

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²

Width in number of modular spacings

4.5

Degree of protection (IP)

IP20

Over voltage category

4

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.