Technical specifications

Rated current2.5A
Rated insulation voltage Ui690V
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Release characteristicB
Number of protected poles3
Built-in depth82.5mm
Number of poles (total)3
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Power loss7.5W
Frequency50 - 60Hz
Current limiting class3
Rated impulse withstand voltage Uimp8kV
Flush-mounted installationYes
Width in number of modular spacings4.5
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Over voltage category4
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
Pollution degree3
Explosion-proofNo
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019893R0001 | S803S-B2.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

2.5A

Rated insulation voltage Ui

690V

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Release characteristic

B

Number of protected poles

3

Built-in depth

82.5mm

Number of poles (total)

3

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

7.5W

Frequency

50 .. 60Hz

Current limiting class

3

Rated impulse withstand voltage Uimp

8kV

Flush-mounted installation

Width in number of modular spacings

4.5

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Over voltage category

4

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Pollution degree

3

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²