Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Over voltage category4
Width in number of modular spacings4.5
Release characteristicC
Rated current1A
Degree of protection (IP)IP20
Frequency50 - 60Hz
Number of protected poles3
Rated insulation voltage Ui690V
Connectable conductor cross section solid-core0 - 70mm²
Pollution degree3
Built-in depth82.5mm
Explosion-proofNo
Current limiting class3
Concurrently switching neutral conductorYes
Voltage typeOther
Power loss4.8W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019898R0001 | S803S-C1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Over voltage category

4

Width in number of modular spacings

4.5

Release characteristic

C

Rated current

1A

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Number of protected poles

3

Rated insulation voltage Ui

690V

Connectable conductor cross section solid-core

0 .. 70mm²

Pollution degree

3

Built-in depth

82.5mm

Explosion-proof

Current limiting class

3

Concurrently switching neutral conductor

Voltage type

Other

Power loss

4.8W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.