Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeOther
Rated current0.5A
Frequency50 - 60Hz
Rated voltage400V
Release characteristicB
Rated insulation voltage Ui690V
Current limiting class3
Over voltage category4
Number of protected poles4
Pollution degree3
Width in number of modular spacings6
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Power loss8W
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section multi-wired0 - 50mm²
Concurrently switching neutral conductorYes
Flush-mounted installationYes
Connectable conductor cross section solid-core0 - 70mm²
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019913R0001 | S804S-B0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

Other

Rated current

0.5A

Frequency

50 .. 60Hz

Rated voltage

400V

Release characteristic

B

Rated insulation voltage Ui

690V

Current limiting class

3

Over voltage category

4

Number of protected poles

4

Pollution degree

3

Width in number of modular spacings

6

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Power loss

8W

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section multi-wired

0 .. 50mm²

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section solid-core

0 .. 70mm²

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Ambient temperature during operating

-25 .. 60°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.