Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Release characteristicC
Width in number of modular spacings6
Pollution degree3
Power loss8.8W
Connectable conductor cross section multi-wired0 - 50mm²
Concurrently switching neutral conductorYes
Number of protected poles4
Connectable conductor cross section solid-core0 - 70mm²
Rated insulation voltage Ui690V
Explosion-proofNo
Rated voltage400V
Over voltage category4
Built-in depth82.5mm
Current limiting class3
Frequency50 - 60Hz
Rated current2A
Voltage typeOther
Flush-mounted installationYes
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019924R0001 | S804S-C2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Release characteristic

C

Width in number of modular spacings

6

Pollution degree

3

Power loss

8.8W

Connectable conductor cross section multi-wired

0 .. 50mm²

Concurrently switching neutral conductor

Number of protected poles

4

Connectable conductor cross section solid-core

0 .. 70mm²

Rated insulation voltage Ui

690V

Explosion-proof

Rated voltage

400V

Over voltage category

4

Built-in depth

82.5mm

Current limiting class

3

Frequency

50 .. 60Hz

Rated current

2A

Voltage type

Other

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.