Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Rated insulation voltage Ui690V
Built-in depth82.5mm
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Width in number of modular spacings6
Rated current4A
Over voltage category4
Pollution degree3
Number of protected poles4
Voltage typeOther
Power loss8W
Explosion-proofNo
Frequency50 - 60Hz
Rated voltage400V
Current limiting class3
Number of poles (total)4
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 70mm²
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019927R0001 | S804S-C4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Width in number of modular spacings

6

Rated current

4A

Over voltage category

4

Pollution degree

3

Number of protected poles

4

Voltage type

Other

Power loss

8W

Explosion-proof

Frequency

50 .. 60Hz

Rated voltage

400V

Current limiting class

3

Number of poles (total)

4

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 70mm²

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.