Aleta.hr
Main Product Image

2CCF019928R0001 | S804S-C5

Code: 1999083

ManufacturerABB
Catalog number2CCF019928R0001
EAN code7612271499945

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Release characteristicC
Rated voltage400V
Rated impulse withstand voltage Uimp8kV
Rated current5A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of protected poles4
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of poles (total)4
Voltage typeOther
Power loss6W
Frequency50 - 60Hz
Flush-mounted installationYes
Concurrently switching neutral conductorYes
Over voltage category4
Pollution degree3
Connectable conductor cross section solid-core0 - 70mm²
Additional equipment possibleYes
Width in number of modular spacings6
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
Degree of protection (IP)IP20
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019928R0001 | S804S-C5

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

C

Rated voltage

400V

Rated impulse withstand voltage Uimp

8kV

Rated current

5A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of protected poles

4

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of poles (total)

4

Voltage type

Other

Power loss

6W

Frequency

50 .. 60Hz

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

4

Pollution degree

3

Connectable conductor cross section solid-core

0 .. 70mm²

Additional equipment possible

Width in number of modular spacings

6

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Degree of protection (IP)

IP20

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.