Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree3
Built-in depth82.5mm
Release characteristicD
Width in number of modular spacings6
Current limiting class3
Frequency50 - 60Hz
Explosion-proofNo
Over voltage category4
Rated voltage400V
Voltage typeOther
Rated insulation voltage Ui690V
Rated current1.6A
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Power loss11.6W
Number of protected poles4
Flush-mounted installationYes
Connectable conductor cross section multi-wired0 - 50mm²
Ambient temperature during operating-25 - 60°C
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Connectable conductor cross section solid-core0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated impulse withstand voltage Uimp8kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019931R0001 | S804S-D1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

3

Built-in depth

82.5mm

Release characteristic

D

Width in number of modular spacings

6

Current limiting class

3

Frequency

50 .. 60Hz

Explosion-proof

Over voltage category

4

Rated voltage

400V

Voltage type

Other

Rated insulation voltage Ui

690V

Rated current

1.6A

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Power loss

11.6W

Number of protected poles

4

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Connectable conductor cross section solid-core

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

8kV

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA