Aleta.hr
Main Product Image

2CCF019932R0001 | S804S-D2

Code: 1999087

ManufacturerRAZNO
Catalog number2CCF019932R0001
Type
EAN code7612271499983

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Built-in depth

82.5mm

Rated current

2A

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of poles (total)

4

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Rated voltage

400V

Voltage type

Other

Frequency

50 - 60Hz

Power loss

8.8W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Yes

Concurrently switching neutral conductor

Yes

Explosion-proof

No

Width in number of modular spacings

6

Flush-mounted installation

Yes

Over voltage category

4

Connectable conductor cross section multi-wired

0 - 50mm²

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 - 70mm²

Ambient temperature during operating

-25 - 60°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCF019932R0001 | S804S-D2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Built-in depth

82.5mm

Rated current

2A

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of poles (total)

4

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Rated voltage

400V

Voltage type

Other

Frequency

50 .. 60Hz

Power loss

8.8W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Concurrently switching neutral conductor

Explosion-proof

Width in number of modular spacings

6

Flush-mounted installation

Over voltage category

4

Connectable conductor cross section multi-wired

0 .. 50mm²

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.