Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Power loss6W
Release characteristicD
Number of protected poles4
Built-in depth82.5mm
Rated current5A
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeOther
Current limiting class3
Rated voltage400V
Concurrently switching neutral conductorYes
Flush-mounted installationYes
Over voltage category4
Degree of protection (IP)IP20
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings6
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 70mm²
Explosion-proofNo
Connectable conductor cross section multi-wired0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019936R0001 | S804S-D5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

6W

Release characteristic

D

Number of protected poles

4

Built-in depth

82.5mm

Rated current

5A

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Current limiting class

3

Rated voltage

400V

Concurrently switching neutral conductor

Flush-mounted installation

Over voltage category

4

Degree of protection (IP)

IP20

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

6

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.