Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeOther
Rated voltage400V
Current limiting class3
Release characteristicD
Rated current5A
Frequency50 - 60Hz
Rated insulation voltage Ui690V
Over voltage category4
Pollution degree3
Width in number of modular spacings6
Number of protected poles4
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core0 - 70mm²
Explosion-proofNo
Power loss6W
Connectable conductor cross section multi-wired0 - 50mm²
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp8kV
Flush-mounted installationYes
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019936R0001 | S804S-D5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

Other

Rated voltage

400V

Current limiting class

3

Release characteristic

D

Rated current

5A

Frequency

50 .. 60Hz

Rated insulation voltage Ui

690V

Over voltage category

4

Pollution degree

3

Width in number of modular spacings

6

Number of protected poles

4

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

Power loss

6W

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

8kV

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA