Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Built-in depth82.5mm
Rated voltage400V
Number of protected poles2
Number of poles (total)2
Rated current1.6A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Frequency50 - 60Hz
Power loss5.8W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Current limiting class3
Concurrently switching neutral conductorYes
Over voltage category4
Flush-mounted installationYes
Width in number of modular spacings3
Degree of protection (IP)IP20
Additional equipment possibleYes
Pollution degree3
Connectable conductor cross section multi-wired0 - 50mm²
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019947R0001 | S802S-K1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Built-in depth

82.5mm

Rated voltage

400V

Number of protected poles

2

Number of poles (total)

2

Rated current

1.6A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Frequency

50 .. 60Hz

Power loss

5.8W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Concurrently switching neutral conductor

Over voltage category

4

Flush-mounted installation

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Additional equipment possible

Pollution degree

3

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.