Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeOther
Rated current2A
Frequency50 - 60Hz
Release characteristicK
Rated voltage400V
Rated insulation voltage Ui690V
Width in number of modular spacings4.5
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Pollution degree3
Rated impulse withstand voltage Uimp8kV
Power loss6.6W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Flush-mounted installationYes
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 70mm²
Number of poles (total)3
Ambient temperature during operating-25 - 60°C
Over voltage category4
Explosion-proofNo
Current limiting class3
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019956R0001 | S803S-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

Other

Rated current

2A

Frequency

50 .. 60Hz

Release characteristic

K

Rated voltage

400V

Rated insulation voltage Ui

690V

Width in number of modular spacings

4.5

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Pollution degree

3

Rated impulse withstand voltage Uimp

8kV

Power loss

6.6W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 70mm²

Number of poles (total)

3

Ambient temperature during operating

-25 .. 60°C

Over voltage category

4

Explosion-proof

Current limiting class

3

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.