Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Release characteristicK
Built-in depth82.5mm
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated current0.5A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Power loss8W
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated insulation voltage Ui690V
Voltage typeOther
Current limiting class3
Number of protected poles4
Rated voltage400V
Over voltage category4
Pollution degree3
Flush-mounted installationYes
Concurrently switching neutral conductorYes
Width in number of modular spacings6
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019961R0001 | S804S-K0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Release characteristic

K

Built-in depth

82.5mm

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated current

0.5A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

8W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated insulation voltage Ui

690V

Voltage type

Other

Current limiting class

3

Number of protected poles

4

Rated voltage

400V

Over voltage category

4

Pollution degree

3

Flush-mounted installation

Concurrently switching neutral conductor

Width in number of modular spacings

6

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²