  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles4
Number of poles (total)4
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Release characteristicK
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated insulation voltage Ui690V
Rated current3A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Power loss9.6W
Current limiting class3
Frequency50 - 60Hz
Built-in depth82.5mm
Flush-mounted installationYes
Concurrently switching neutral conductorYes
Over voltage category4
Connectable conductor cross section solid-core0 - 70mm²
Additional equipment possibleYes
Degree of protection (IP)IP20
Explosion-proofNo
Width in number of modular spacings6
Pollution degree3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019966R0001 | S804S-K3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

4

Number of poles (total)

4

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Release characteristic

K

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated insulation voltage Ui

690V

Rated current

3A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

9.6W

Current limiting class

3

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

4

Connectable conductor cross section solid-core

0 .. 70mm²

Additional equipment possible

Degree of protection (IP)

IP20

Explosion-proof

Width in number of modular spacings

6

Pollution degree

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²