  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage-V
Number of protected poles1
Rated current4A
Number of poles (total)1
Rated insulation voltage Ui1500V
Built-in depth82.5mm
Release characteristicOther
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss2W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Frequency0 - 0Hz
Voltage typeOther
Concurrently switching neutral conductorYes
Flush-mounted installationYes
Width in number of modular spacings1.5
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
Pollution degree2
Degree of protection (IP)IP20
Over voltage category3
Additional equipment possibleYes
Explosion-proofNo
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019975R0001 | S801S-UCB4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

-V

Number of protected poles

1

Rated current

4A

Number of poles (total)

1

Rated insulation voltage Ui

1500V

Built-in depth

82.5mm

Release characteristic

Other

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Frequency

0 .. 0Hz

Voltage type

Other

Concurrently switching neutral conductor

Flush-mounted installation

Width in number of modular spacings

1.5

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Pollution degree

2

Degree of protection (IP)

IP20

Over voltage category

3

Additional equipment possible

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²