Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Built-in depth82.5mm
Rated insulation voltage Ui1500V
Voltage typeOther
Pollution degree2
Frequency0 - 0Hz
Release characteristicOther
Rated current1.6A
Degree of protection (IP)IP20
Over voltage category3
Rated voltage-V
Explosion-proofNo
Number of protected poles1
Width in number of modular spacings1.5
Power loss2.9W
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section solid-core0 - 70mm²
Ambient temperature during operating-25 - 60°C
Flush-mounted installationYes
Additional equipment possibleYes
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019981R0001 | S801S-UCK1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Built-in depth

82.5mm

Rated insulation voltage Ui

1500V

Voltage type

Other

Pollution degree

2

Frequency

0 .. 0Hz

Release characteristic

Other

Rated current

1.6A

Degree of protection (IP)

IP20

Over voltage category

3

Rated voltage

-V

Explosion-proof

Number of protected poles

1

Width in number of modular spacings

1.5

Power loss

2.9W

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Additional equipment possible

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.