Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Width in number of modular spacings1.5
Rated current8A
Built-in depth82.5mm
Over voltage category3
Degree of protection (IP)IP20
Frequency0 - 0Hz
Pollution degree2
Release characteristicOther
Current limiting class3
Number of protected poles1
Rated insulation voltage Ui1500V
Rated voltage-V
Power loss1.7W
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Number of poles (total)1
Additional equipment possibleYes
Concurrently switching neutral conductorYes
Flush-mounted installationYes
Connectable conductor cross section solid-core0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019988R0001 | S801S-UCK8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Width in number of modular spacings

1.5

Rated current

8A

Built-in depth

82.5mm

Over voltage category

3

Degree of protection (IP)

IP20

Frequency

0 .. 0Hz

Pollution degree

2

Release characteristic

Other

Current limiting class

3

Number of protected poles

1

Rated insulation voltage Ui

1500V

Rated voltage

-V

Power loss

1.7W

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of poles (total)

1

Additional equipment possible

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section solid-core

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

8kV