  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current8A
Release characteristicOther
Built-in depth82.5mm
Number of poles (total)2
Number of protected poles2
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui1500V
Rated voltage-V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency0 - 0Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Power loss3.4W
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Over voltage category3
Additional equipment possibleYes
Concurrently switching neutral conductorYes
Width in number of modular spacings3
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
Flush-mounted installationYes
Ambient temperature during operating-25 - 60°C
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019998R0001 | S802S-UCB8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

8A

Release characteristic

Other

Built-in depth

82.5mm

Number of poles (total)

2

Number of protected poles

2

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

1500V

Rated voltage

-V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

0 .. 0Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Power loss

3.4W

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Over voltage category

3

Additional equipment possible

Concurrently switching neutral conductor

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Pollution degree

2