  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp8kV
Rated current8A
Rated insulation voltage Ui1500V
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Built-in depth82.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Release characteristicOther
Power loss5.1W
Frequency0 - 0Hz
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Voltage typeOther
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated voltage-V
Flush-mounted installationYes
Over voltage category3
Pollution degree2
Width in number of modular spacings4.5
Additional equipment possibleYes
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF020018R0001 | S803S-UCB8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

8kV

Rated current

8A

Rated insulation voltage Ui

1500V

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Release characteristic

Other

Power loss

5.1W

Frequency

0 .. 0Hz

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated voltage

-V

Flush-mounted installation

Over voltage category

3

Pollution degree

2

Width in number of modular spacings

4.5

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²