Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)3
Release characteristicOther
Built-in depth82.5mm
Rated voltage-V
Rated impulse withstand voltage Uimp8kV
Number of protected poles3
Rated current1A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated insulation voltage Ui1500V
Voltage typeOther
Power loss4.8W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Current limiting class3
Frequency0 - 0Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Flush-mounted installationYes
Pollution degree2
Concurrently switching neutral conductorYes
Over voltage category3
Width in number of modular spacings4.5
Additional equipment possibleYes
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 70mm²
Connectable conductor cross section multi-wired0 - 50mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF020020R0001 | S803S-UCK1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Release characteristic

Other

Built-in depth

82.5mm

Rated voltage

-V

Rated impulse withstand voltage Uimp

8kV

Number of protected poles

3

Rated current

1A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated insulation voltage Ui

1500V

Voltage type

Other

Power loss

4.8W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Frequency

0 .. 0Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Flush-mounted installation

Pollution degree

2

Concurrently switching neutral conductor

Over voltage category

3

Width in number of modular spacings

4.5

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 70mm²

Connectable conductor cross section multi-wired

0 .. 50mm²

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.