Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth82.5mm
Rated current1.6A
Width in number of modular spacings4.5
Power loss8.7W
Explosion-proofNo
Pollution degree2
Degree of protection (IP)IP20
Over voltage category3
Current limiting class3
Connectable conductor cross section solid-core0 - 70mm²
Concurrently switching neutral conductorYes
Rated voltage-V
Flush-mounted installationYes
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Frequency0 - 0Hz
Rated insulation voltage Ui1500V
Number of protected poles3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp8kV
Release characteristicOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF020021R0001 | S803S-UCK1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

82.5mm

Rated current

1.6A

Width in number of modular spacings

4.5

Power loss

8.7W

Explosion-proof

Pollution degree

2

Degree of protection (IP)

IP20

Over voltage category

3

Current limiting class

3

Connectable conductor cross section solid-core

0 .. 70mm²

Concurrently switching neutral conductor

Rated voltage

-V

Flush-mounted installation

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

0 .. 0Hz

Rated insulation voltage Ui

1500V

Number of protected poles

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Release characteristic

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA