Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicOther
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Voltage typeOther
Frequency0 - 0Hz
Rated insulation voltage Ui1500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Number of protected poles3
Power loss7.5W
Rated impulse withstand voltage Uimp8kV
Built-in depth82.5mm
Rated voltage-V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated current2.5A
Current limiting class3
Flush-mounted installationYes
Ambient temperature during operating-25 - 60°C
Over voltage category3
Width in number of modular spacings4.5
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 50mm²
Explosion-proofNo
Pollution degree2
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF020023R0001 | S803S-UCK2.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Other

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Frequency

0 .. 0Hz

Rated insulation voltage Ui

1500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of protected poles

3

Power loss

7.5W

Rated impulse withstand voltage Uimp

8kV

Built-in depth

82.5mm

Rated voltage

-V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

2.5A

Current limiting class

3

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

Width in number of modular spacings

4.5

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 50mm²

Explosion-proof

Pollution degree

2

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.