Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated current2.5A
Rated voltage-V
Built-in depth82.5mm
Frequency0 - 0Hz
Degree of protection (IP)IP20
Number of protected poles4
Pollution degree2
Rated insulation voltage Ui1500V
Power loss10W
Connectable conductor cross section multi-wired0 - 50mm²
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Current limiting class3
Explosion-proofNo
Additional equipment possibleYes
Flush-mounted installationYes
Over voltage category3
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core0 - 70mm²
Width in number of modular spacings6
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Release characteristicOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF020033R0001 | S804S-UCB2.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated current

2.5A

Rated voltage

-V

Built-in depth

82.5mm

Frequency

0 .. 0Hz

Degree of protection (IP)

IP20

Number of protected poles

4

Pollution degree

2

Rated insulation voltage Ui

1500V

Power loss

10W

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Current limiting class

3

Explosion-proof

Additional equipment possible

Flush-mounted installation

Over voltage category

3

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 70mm²

Width in number of modular spacings

6

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Release characteristic

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.